Technical Specifications
A. Manufacturing
Foam-in-place insulation shall be Tripolymer® PRMIU or 105 manufactured by C.P. Chemical Company. Both the A component (resin) and B component (catalyst) shall bear the manufacturing lot #, date and product descriptions
B. Material
The foam-in-place Tripolymer® system shall consist of the A component (resin) and B component (catalyst) supplied by C.P. Chemical. Thickness shall be in accordance with architectural drawings. The insulation shall have the following physical properties:
1. Density of.8 – 1.3 lb/ft.3
2. Compressive strength 35 psi.
3. Fire Characteristics ASTM E-84
Flame Spread 5
Smoke 0
Fuel 0
4. Thermal Conductivity C-177. @74° F
K factor of 0.219 BTU in/hr – ft2 F
5. Water Vapor Transmission ASTM C- 355
Permeability – perms-in 15.5 to 16.9
6. Fire Hour Rating ASTM E- 119 – 2 Hrs.
C. Installation
Materials shall be installed according to the manufacturer’s instructions through equipment manufactured by C.P. Chemical and by a factory trained/certified insulation contractor with a current certification card.
Product Description
Tripolymer® products are phenolic-based methylene linked synthetic polymers. They are made exclusively by C.P. Chemical Company, Inc. Both the chemical and equipment are patented products. The Tripolymer® system consists of two components: an aqueous resin solution (A) and foaming agent/catalysts (B). These materials are ratioed together with compressed air in specially engineered metering and pumping equipment.
Installation
Tripolymer® can be installed in any cavity through 1” – 2” holes or sprayed into new stud construction. Initial set takes approximately 10 – 30 seconds. Final curing is within 48 – 72 hrs., depending upon thickness. Tripolymer® is a cold setting process independent of ambient temperatures. There is not further expansion once the foam leaves the delivery hose.
Tripolymer® is installed by C.P. Chemical’s network of certified insulation applicators. Specially engineered equipment have been designed by C.P. Chemical Company for the application of Tripolymer® insulation and are required in the installation of the foam.
Thermal Stability
There is no thermal degradation or reduction in R value over time with Tripolymer® products . Most polyisocyanurates, polyurethane, and expanded polystyrenes degrade over time, resulting in lower R values.
NOTE: Tripolymer® is not a polyurethane, polyisocyanurate or expanded polystyrene product. It does not contain any petrochemicals or fire retardant chemicals. Tripoylmer®, when exposed to intensive heat or flame, does not drip or produce smoke.
Limitations
This material should not be used against surfaces with temperature in excess of 212°F for prolonged periods of time. The foam will not support compressive load nor should it be used for flotation, or underground without adequate protection.
Original Equipment Manufacturing
Tripolymer® is an excellent product for continuous process manufacturing and original equipment manufacturing .Computerized equipment for in-plant installations of Tripolymer® is available. This equipment can be adapted for a number of OEW purposes. For additional information, please contact C.P. Chemical.
|
| Properties |
ASTM Test Method |
Results |
| Fire Hour Rating |
ASTM E-119 |
Upon Request |
| Thermal Conductivity (1) |
ASTM C-177 |
|
| R, HR. Ft2 - °F/BTU |
|
|
| @75°F mean |
|
4.8 |
| @35°F mean |
|
5 |
| |
|
|
| Surface Burning Characteristics |
ASTM E-84 |
|
| Flame Spread |
|
5 |
| Smoke Development |
|
0 |
| |
|
|
| Heat of Combustion |
ASTM D-240-73 |
6,435 btu per lb. |
| Corrosiveness |
DOE (e)(3)
HUD 6.2.8 |
No perforations
No pulling
Less than 0.05 g |
| Water Vapor Transmission |
ASTM C-355 |
|
| Perms in. |
|
15.9 – 16. 9 |
| Sound Transmission Loss |
ASTM E413- 73 |
STC 53 |
| Density |
ASTM D-1622 |
|
| Lbs./Ft.3 |
|
0.8-1.2 |
| Compression Strength |
ASTM D-1621 |
|
| Psi |
Proc A |
5- 45 |
| Gel Time |
DDF (3)(8)
HUD 6.2.3 |
25 sec. |
| Shrinkage (variable) |
HUD Procedure |
Approx., .5-1.5% |
| Fungi Resistance |
HUD Procedure |
No Growth |
| Taxicity |
FHSA |
Non Toxic |
| Thickness |
@35°F Mean
Temperature |
@75°F Mean Temperature |
| ¾” |
3.75 |
3.6 |
| 1” |
5 |
4.8 |
| 1-1/2” |
7.5 |
7.2 |
| 2” |
10 |
9.6 |
| 3-1/2” |
17.5 |
16.8 |
| 4” |
20 |
16.8 |
|